sql

DO Meter Hanna HI 9142

Rp. CALL
Last Updated
10 Nov 2023
Country Origin
Hungary
Minimum Order
1 Unit

HI9142


Manual Calibration Dissolved Oxygen Meter


•             Automatic
Temperature Compensation (ATC)


•             One or
two-point calibration


•             Waterproof


 The ever increasing demand for instant on-site analysisresults has created a need for innovative, rugged, portable and waterproof meters.Field work can subject instrumentation to the inclemency ofweather. Cold, rain, snow, dust and humidity can cause condensation to breech the housing. Once the housing has been compromised, the meter is susceptible to diminishing performance and life span. The rugged, waterproof housing of the HI9142 solves many of the problems of field use.


Calibration is performed with HI7040 zero oxygen solution,while 100% calibration is done in air.


 The polarographic probe (HI76407/4) is accurate to 0.3 ppmand is supplied with a 4 m (13’) cable that allows measurements to be taken even in hard to reach places.


Specifications

Dissolved Oxygen           


              Range     0.0 to 19.9 mg/L (ppm)


                Resolution          0.1 mg/L (ppm)


                Accuracy
(@ 25°C/77°F) ±1.5% F.S.


Temperature    


              Range     -5.0 to 50.0°C (23.0 to 122.0°F)


                Resolution          0.1°C (1°F)


                Accuracy
(@ 25°C/77°F) ±0.2°C (±1°F) (excluding
probe error)


 Additional Specifications              


Calibration          automatic
in zero oxygen solution; manual in 100% water saturated air


                Temperature
Compensation     


automatic, 0 to 50°C (32 to 122°F)


               


Probe    HI76407/4
polarographic DO probe with internal temperature sensor, DIN connector and 4 m
(13’) cable


               


Battery Type / Life           1.5V
AAA (3) / approximately 1,000 hours of continuous use


                Environment      0 to 50°C (32 to 122°F); RH max 100%


                Dimensions        185 x 72 x 36 mm (7.3 x 2.8 x 1.4”)


                Weight 300 g (10.6 oz.)


Ordering Information     HI9142
is supplied with HI 76407/4 probe with 4 m (13’) cable, 2 spare membranes,
HI7041S electrolyte solution (30 mL), calibration screwdriver, batteries,
instructions and rugged carrying case.